Home Surgical Solutions Tenore
- ULTRASONIC SURGICAL SHEAR · EL-TEN36
Tenore Curved Shears
“Created by Surgeons, for Surgeons.”`
A precision ultrasonic shear delivering safe, low-thermal, multi-function cutting and sealing — with intuitive surgeon-friendly control.
Home Surgical Solutions Tenore
- ULTRASONIC SURGICAL SHEAR · EL-TEN36
Tenore Curved Shears
“Created by Surgeons, for Surgeons.”`
A precision ultrasonic shear delivering safe, low-thermal, multi-function cutting and sealing — with intuitive surgeon-friendly control.
Ultrasonic Energy
Low Thermal Spread
7mm Port Compatible
Vessel Sealing ≤5mm
Ultrasonic Energy
Low Thermal Spread
5mm Port Compatible
Vessel Sealing ≤5mm
- KEY BENEFITS
Engineered for the Demands of Modern Surgery.
The Tenore Curved Shear gives the operating surgeon precision, efficiency, and confidence — in a single instrument that replaces multiple conventional tools.
Precision
Directed Mechanical Energy
Mechanical energy works at lower temperatures and is directed longitudinally — delivering targeted tissue dissection without the unpredictability of electrical energy spread.
Safety
Minimal Thermal Spread
Safe to use near vital structures — minimal smoke or eschar. The lower thermal profile significantly reduces the risk of inadvertent thermal injury to adjacent tissue.
Efficiency
One Device, Five Functions
Ergonomics
Intuitive Surgeon Control
Open handle with hook trigger for comfort, balance and control. Soft moulding maximises grip. Minimum index finger repositioning needed during extended procedures.
Feedback
Audible & Tactile Feedback
The trigger clicks when jaws are fully compressed and again when released — giving the surgeon reliable tactile and audible confirmation during tissue engagement.
Versatility
Vessel Sealing ≤5mm
Seals and divides vessels up to 5mm including lymphatics. Vessels are sealed or welded together with coagulum that does not stick to the blade — clean, reliable ligation.
- KEY BENEFITS
Engineered for the Demands of Modern Surgery.
The Tenore Curved Shear gives the operating surgeon precision, efficiency, and confidence — in a single instrument that replaces multiple conventional tools.
Precision
Directed Mechanical Energy
Mechanical energy works at lower temperatures and is directed longitudinally — delivering targeted tissue dissection without the unpredictability of electrical energy spread.
Safety
Minimal Thermal Spread
Safe to use near vital structures — minimal smoke or eschar. The lower thermal profile significantly reduces the risk of inadvertent thermal injury to adjacent tissue.
Efficiency
One Device, Five Functions
Dissect, cut, seal, grasp, spot-coagulate, and create otomies — all from a single instrument. Fewer instrument exchanges, reduced OR time, cleaner operative field.
Ergonomics
Intuitive Surgeon Control
Open handle with hook trigger for comfort, balance and control. Soft moulding maximises grip. Minimum index finger repositioning needed during extended procedures.
Feedback
Audible & Tactile Feedback
The trigger clicks when jaws are fully compressed and again when released — giving the surgeon reliable tactile and audible confirmation during tissue engagement.
Versatility
Vessel Sealing ≤5mm
Seals and divides vessels up to 5mm including lymphatics. Vessels are sealed or welded together with coagulum that does not stick to the blade — clean, reliable ligation.
- HOW IT WORKS
Four Tissue Effects. One Ultrasonic Instrument.
Directed ultrasonic energy works in four clinically distinct ways — giving the surgeon a full spectrum of tissue interaction from a single shear.

01
Effect 01
Cutting
Mechanical vibration at the blade tip directly transects tissue with precision — delivering a clean, controlled cut along anatomical planes.

01
Effect 02
Coagulation
Frictional heat generated at the blade seals blood vessels — achieving haemostasis without delivering electrical current to the patient.

01
Effect 03
Coaptation
Tissue adherence — vessel walls are pressed together and fused (welded) under ultrasonic energy, creating a secure, reliable seal.

01
Effect 04
Cavitation
Ultrasonic vibration creates body-temperature vapour around the active blade — aiding tissue plane dissection, especially near vital structures.
- HOW IT WORKS
Four Tissue Effects. One Ultrasonic Instrument.
Directed ultrasonic energy works in four clinically distinct ways — giving the surgeon a full spectrum of tissue interaction from a single shear.

01
Effect 01
Cutting
Mechanical vibration at the blade tip directly transects tissue with precision — delivering a clean, controlled cut along anatomical planes.

01
Effect 02
Coagulation
Frictional heat generated at the blade seals blood vessels — achieving haemostasis without delivering electrical current to the patient.

01
Effect 03
Coaptation
Tissue adherence — vessel walls are pressed together and fused (welded) under ultrasonic energy, creating a secure, reliable seal.

01
Effect 04
Cavitation
Ultrasonic vibration creates body-temperature vapour around the active blade — aiding tissue plane dissection, especially near vital structures.

0
Flat Back Surface
The flat back of the blade is optimised for broad coagulation — providing a wide sealing surface for tissue haemostasis.

0
Curved Blade
The curved jaw design enables precise dissection with clear tip visibility — essential for anatomically complex laparoscopic fields.



0
Clamping Surface
Serrated clamping surface for cutting, coagulation, and grasping — a multi-functional jaw for complete tissue management in one position.

0
Blunt Nose
Blunt nose tip for precision blunt dissection — allows safe navigation near neurovascular structures without inadvertent sharp injury.

0
Cutting Edge
Dedicated cutting edge for tissue scoring or back-cutting along anatomical planes — enabling precise layered dissection.

0
Flat Back Surface
The flat back of the blade is optimised for broad coagulation — providing a wide sealing surface for tissue haemostasis.

0
Curved Blade
The curved jaw design enables precise dissection with clear tip visibility — essential for anatomically complex laparoscopic fields.



0
Clamping Surface
Serrated clamping surface for cutting, coagulation, and grasping — a multi-functional jaw for complete tissue management in one position.

0
Blunt Nose
Blunt nose tip for precision blunt dissection — allows safe navigation near neurovascular structures without inadvertent sharp injury.

0
Cutting Edge
Dedicated cutting edge for tissue scoring or back-cutting along anatomical planes — enabling precise layered dissection.
- CLINICAL APPLICATIONS
Where Tenore Performs
Tenore Curved Shears are indicated across all major laparoscopic specialties — wherever precise dissection, reliable sealing, and minimal thermal injury are required.
01
General Surgery
01
Gynecology
01
Urology
01
Thoracic Surgery
- CLINICAL APPLICATIONS
Where Tenore Performs
Tenore Curved Shears are indicated across all major laparoscopic specialties — wherever precise dissection, reliable sealing, and minimal thermal injury are required.
01
General Surgery
Cholecystectomy, appendectomy, bowel resection, hernia repair, and hepatobiliary procedures.
01
Gynecology
Laparoscopic hysterectomy, myomectomy, salpingectomy, and oophorectomy.
01
Urology
Nephrectomy, prostatectomy, pyeloplasty, and urological dissection in confined retroperitoneal spaces.
01
Thoracic Surgery
VATS procedures — pulmonary lobectomy, mediastinal dissection, and thoracoscopic tissue management.
- TECHNICAL SPECIFICATIONS
Full Product Specifications
Complete technical data for the Tenore Curved Shear system — including compatible accessories and product codes.
TENORE SHEAR — EL-TEN36
EL-DS45
Detachable Shear 45cm (Disposable)
EL-DS36
Detachable Shear 36cm (Disposable)
EL-DS23
Detachable Shear 23cm (Disposable)
EL-DS14
Detachable Shear 14cm (Disposable)
EL-TEN36
Tenore Curved Shear 36cm
EL-SH14
Integrated Shear 14cm (Disposable)
EL-SH23
Integrated Shear 23cm (Disposable)
EL-SH36
Integrated Shear 36cm (Disposable)
- TECHNICAL SPECIFICATIONS
Full Product Specifications
Complete technical data for the Tenore Curved Shear system — including compatible accessories and product codes.
TENORE SHEAR — EL-TEN36
Tenore Curved Shear (Integrated with handle)
EL-TEN36
36cm
Disposable
Integrated shear with handle
Curved jaw, blunt nose
≤5mm(incl. lymphatics)
Ultrasonic
Low — directed longitudinal
MASTERDOM-25, ANY OTHER GENERATOR
EL-DS45
Detachable Shear 45cm (Disposable)
EL-DS36
Detachable Shear 36cm (Disposable)
EL-DS23
Detachable Shear 23cm (Disposable)
EL-DS14
Detachable Shear 14cm (Disposable)
EL-TEN36
Tenore Curved Shear 36cm
EL-SH14
Integrated Shear 14cm (Disposable)
EL-SH23
Integrated Shear 23cm (Disposable)
EL-SH36
Integrated Shear 36cm (Disposable)
- ROI & BUSINESS BENEFITS
The Business Case for Tenore
Switching to ultrasonic dissection with Tenore delivers measurable operational and financial benefits for hospitals and surgical centres.
01
Reduced OR Time
One instrument replaces multiple conventional tools — fewer exchanges, less setup, faster procedure completion. More cases per list.
02
Lower Complication Rate
Minimal thermal spread reduces risk of inadvertent injury near vital structures — fewer post-op complications, shorter hospital stay, lower cost per case.
03
Faster Patient Recovery
Reduced thermal tissue trauma supports faster patient recovery — shorter LOS, higher patient throughput, and better clinical outcomes scores.
04
Reduced Consumable Complexity
Disposable integrated shear simplifies procurement and sterilisation logistics — no reprocessing cost, predictable per-case expenditure.
- ROI & BUSINESS BENEFITS
The Business Case for Tenore
Switching to ultrasonic dissection with Tenore delivers measurable operational and financial benefits for hospitals and surgical centres.
01
Reduced OR Time
One instrument replaces multiple conventional tools — fewer exchanges, less setup, faster procedure completion. More cases per list.
02
Lower Complication Rate
Minimal thermal spread reduces risk of inadvertent injury near vital structures — fewer post-op complications, shorter hospital stay, lower cost per case.
03
Faster Patient Recovery
Reduced thermal tissue trauma supports faster patient recovery — shorter LOS, higher patient throughput, and better clinical outcomes scores.
04
Reduced Consumable Complexity
Disposable integrated shear simplifies procurement and sterilisation logistics — no reprocessing cost, predictable per-case expenditure.
- SAFETY PROFILE
Engineered Safe. Clinically Proven.
The Tenore Curved Shear is designed with patient and surgeon safety at the core of every design decision — from blade geometry to energy delivery.
01
Low Thermal Profile
Mechanical energy directed longitudinally produces significantly less lateral thermal spread than monopolar or bipolar electrosurgery — reducing risk of inadvertent thermal injury to adjacent tissue and organs.
02
No Electrical Current to Patient
Ultrasonic energy is purely mechanical — no electrical current is delivered to the patient. This eliminates the risk of capacitive coupling, stray currents, and return electrode burns associated with electrosurgery.
03
Blunt Nose for Vital Structures
The blunt nose tip is specifically designed to allow safe blunt dissection near critical neurovascular structures — enabling confident navigation in anatomically sensitive surgical fields.
04
No Coagulum Blade Sticking
Unlike conventional electrosurgical instruments, coagulum does not adhere to the Tenore blade — reducing tissue drag, maintaining cleaner operative field, avoiding inadvertent tissue disruption during instrument withdrawal.
05
Minimal Smoke & Eschar
Ultrasonic tissue transection produces significantly less surgical smoke than electrosurgery — improving intraoperative visibility, reducing theatre air contamination, and enhancing surgical team safety.
06
Tactile Safety Feedback
Audible and tactile trigger click system confirms jaw engagement and release — giving the surgeon real-time confirmation of tissue position and preventing inadvertent activation.
- SAFETY PROFILE
Engineered Safe. Clinically Proven.
The Tenore Curved Shear is designed with patient and surgeon safety at the core of every design decision — from blade geometry to energy delivery.
01
Low Thermal Profile
Mechanical energy directed longitudinally produces significantly less lateral thermal spread than monopolar or bipolar electrosurgery — reducing risk of inadvertent thermal injury to adjacent tissue and organs.
02
No Electrical Current to Patient
Ultrasonic energy is purely mechanical — no electrical current is delivered to the patient. This eliminates the risk of capacitive coupling, stray currents, and return electrode burns associated with electrosurgery.
03
Blunt Nose for Vital Structures
The blunt nose tip is specifically designed to allow safe blunt dissection near critical neurovascular structures — enabling confident navigation in anatomically sensitive surgical fields.
04
No Coagulum Blade Sticking
Unlike conventional electrosurgical instruments, coagulum does not adhere to the Tenore blade — reducing tissue drag, maintaining cleaner operative field, avoiding inadvertent tissue disruption during instrument withdrawal.
05
Minimal Smoke & Eschar
Ultrasonic tissue transection produces significantly less surgical smoke than electrosurgery — improving intraoperative visibility, reducing theatre air contamination, and enhancing surgical team safety.
06
Tactile Safety Feedback
Audible and tactile trigger click system confirms jaw engagement and release — giving the surgeon real-time confirmation of tissue position and preventing inadvertent activation.
Download the Tenore
Clinical Brochure
Full product specifications, clinical data, tissue effect diagrams, and the complete ElnEl surgical catalogue — available for download.
Download the Tenore
Clinical Brochure
Full product specifications, clinical data, tissue effect diagrams, and the complete ElnEl surgical catalogue — available for download.
- TRUSTED BY
Request a Demo or Enquiry
ADDRESS
El n EL Industries Pvt. Ltd., Plot No. 2/B, Nr Shivam Estate 5, Changodar, Ahmedabad, Gujarat, 38221
PHONE / WHATSAPP
+91 80 6900 0029
EMAIL
info@elnel.in
WEBSITE
CONTACT/ENQUIRE
Become a Partner ,See a Demo Become a Distributor